Product Lightning Protection System Accessories

Several Accessories are used in the installation of Lightning protection systems such as masts, Down conductors, lightning event counters, Terminal tester etc.

LIGHTNING STRIKE COUNTER:

MODEL: LSC
ENCLOSURE RATING: IP 67
DIMENSION: 11.3 x 7 x 4.8 CM

  • Produced according to IP 67
  • Non-resettable
  • Currents detected from 2 to 100 KA
  • Does not require external Power supply
  • Certified by METU-Middle East Technical University
  • LSC works with an inductive effect of the lighting strike current the events are monitored by a mechanical counter display
  • LSC is a serial counter with 6 digit mechanical display unit

FEATURES:

  • The Lightning strikes are detected and monitored by LSC, which is able to give some information about the service necessity of the lightning system. By using an inductive record, the counter is able to accurately count all lightning events for a later reference
  • LSC works with an inductive effect of the lightning strike current. The events are monitored by a mechanical counter display
  • LSC is a serial counter with 6digit mechanical display unit
  • It detect the lightning currents, which is more than 2KA
  • LSC does not require any external power supply
  • The lightning event counter shall be installed to the manufacturer’s instructions in a readily accessible manner so that readings can be taken at regular intervals. It shall be positioned such that it’s operating temperature is in the range of –10 deg C to +50 deg C
  • The lightning event counter shall be robust, easy to install and housed in an IP67 rated enclosure. The counter shall operate from the energy of the lightning discharge and not rely on external or battery power to operate

AIR TERMINAL TESTER:
MODEL: LC
ENCLOSURE RATING: IP 67
DIMENSION: 11.3 x 7 x 4.8 CM

FEATURES:

  • The Lightning terminal can be checked by the forend tester any time
  • The tester will indicate OK or FAULT with the help of red or green LED
  • The test can be done from 100mtrs by means of connection cable
FRP Mast

FRP Mast
Aluminium Mast

Aluminium Mast
Stainless Steel Mast

Stainless Steel Mast
GI Mast

GI Mast
Down conductor

Down conductor
Different types of don conductors are used such as 25*3mm Cu tape or 25*3mm GI tape or 600V graede-50sq.mm, PVC insulated cable.

Copper tape, 25*3 mm.
Copper cable, 600V grade, 50 sq.mm, PVC insulated cable
GI tape, 25*3mm.


Down conductor

Maintenance free radial earthing
TYPE: RADIAL (As surface earthing is recommended for lightning protection in stead of dipper earthing)
SPEC: IS 2309
LENGTH OF EACH COPPER ELECTRODE: 5FT
MINIMUM NO OF COPPER ELECTRODE: 4NOS

FEATURES:

  • The permanent & maintenance free grounding system shall consist of 4 numbers of inter connected ground pits made up of UL approved copper bonded steel ground Rods of dia 5/8 inch & length 5 feet installed in 4 inch dia bore treated with ground enhancement material ZEROLITE.